Uploaded image for project: 'CMS'
  1. CMS
  2. CMS-8168

The datasources of FO application are synchronized multiple times

    • Icon: Bug Bug
    • Resolution: Fixed
    • Icon: Major Major
    • 4.0RC5
    • 4.0RC3
    • None
    • None

      Once per restarting

      I think there is a probleme when a datasource is used in a population, because there is an error when a used population is tried to be sunchronized from BO app to FO app

          [CMS-8168] The datasources of FO application are synchronized multiple times

          Simon Prieul (Inactive) made changes -
          Status Original: Resolved [ 5 ] New: Closed [ 6 ]
          Laurence Aumeunier made changes -
          Fix Version/s New: 4.0RC5 [ 14110 ]
          Fix Version/s Original: 4.0 [ 12884 ]
          Raphaël Franchet made changes -
          Resolution New: Fixed [ 1 ]
          Status Original: Open [ 1 ] New: Resolved [ 5 ]

          The issue happens only if you share the datasource storing the associations between contexts and populations ; between FO and BO...
          I will change the API to allow the removal of a population even if it seems to be used

          Raphaël Franchet added a comment - The issue happens only if you share the datasource storing the associations between contexts and populations ; between FO and BO... I will change the API to allow the removal of a population even if it seems to be used
          Simon Prieul (Inactive) made changes -
          Simon Prieul (Inactive) created issue -

            raphael Raphaël Franchet
            sprieul Simon Prieul (Inactive)
            Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

              Created:
              Updated:
              Resolved: